Software Updates

Grace Instrument occasionally updates instrument software to fix errors and enhance the user experience. Please check below to see if there are any software updates for your instrument.

SOFTWARE UPDATE INFORMATION

NOTE: All Grace Instrument software must be installed from an installation CD or other installation media provided by Grace Instrument in order to function properly, and the user must be logged into the PC using an Administrator account during installation. One copy of the necessary installation media is included with each instrument. If you have not installed the Grace Instrument software from your original installation CD or media, the updates available for download from this site cannot be applied, and the Grace Instrument software will not run.
  1. Replacement installation media can be ordered from Grace Instrument at any time.
  2. After the initial setup of your Grace Instrument product is complete, please take care that any installation media (CD or other digital delivery mechanism) that came with the Operation Manual is kept in a safe place and is accessible, should the need arise to reinstall the Grace Instrument software.
  3. Should this media become lost or damaged, you will need to contact Grace Instrument to obtain replacement installation media. Replacement media for Grace Instrument software will be provided at a cost of $199.00 per unit for out-of-warranty customers. Each copy will have a unique serial number for tracking purposes and will be shipped within one (1) business day.
  1. Unless otherwise indicated, all Grace Instrument software is compatible with all Microsoft Windows versions from Windows 9x to Windows 8.1, both 32-bit and 64-bit. Grace Instrument software must be installed and run from an Administrator account.

  1. If you are using an older USB to Serial Adaptor cable, please refer to this USB Serial Adaptors Com Port Instructions guide. It may be advisable to add an upgraded USB to Serial adaptor to your replacement installation media order, as we are unable to supply drivers for out-of-warranty USB to Serial adaptors.
  2. The Grace Instrument software installation media which accompanied your Grace Instrument product contains drivers which are compatible with the USB to Serial Adaptors which may have also accompanied your Grace Instrument product. These drivers are available for download free of charge, should you need to reinstall them.
  3. Download the file linked below and unzip it to a directory on your hard drive. When reinstalling the drivers, use the Browse button to choose the directory where you unzipped the files. Download the latest file here:
    USB to Serial Adaptor drivers - (3.57 MB file)

Before upgrading, installing, or uninstalling any Grace Instrument software, it is strongly advised to make a backup copy of any existing database file(s). This is to ensure all saved test data, including user-created tests and all test results, are backed up and saved.

If you value your existing test data, it is strongly advised that you follow the instructions below and keep backup file(s) stored in a safe location. Make backups periodically as needed to ensure your data is safe. Two backup copies of each database file required for your machine are recommended, one on your PC and one on an external USB. It is strongly recommended to place each backup database file in a separate folder, labeled with a reference to the directory in which it was found, for future reference.


To back up your database file(s), perform the following:
Step 1: Log into the administrator account that performs or will perform testing.

Step 2: Press the Windows Key and E (⊞ + E) to open Windows Explorer.

Step 3: From Windows Explorer, open the C:\ drive.

(To do this, copy and paste C:\ into the directory bar located near the top of the window.)

(When the software was installed to the PC for the first time, it should have installed to a folder in the C:\ drive by default unless otherwise specified by the user. If you instructed the software to install on a different drive, open that drive instead.)

Step 4: In the search bar located in the top right of Windows Explorer, type .mdb, then press Enter to search the drive for .mdb files. Next, search for .accdb and .laccdb files.

Step 5: Take note of the location(s) in which the database file(s) (.mdb, .accdb, and/or .laccdb files) for the machine exist. The following expandable subsections list common locations these database file(s) may reside depending on the operating system. Before proceeding, doublecheck the locations that may correspond to your operating system below to ensure you have every database file needed (IN ADDITION to any others that appear in the search results for the machine).

The default installation folder under Windows 9x to XP for most Grace Instrument software is:

C:\Program Files\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION]

For example, M3600DAQ™ for the M3600 Rheometer is installed in the folder:

C:\Program Files\M3600DAQ

Or, if you specified a different folder during initial installation, open that folder instead.

The default installation folder containing your database file(s) under Windows Vista or 7 is:

C:\Program Files\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION]

For example, the M5600 .accdb database for M5600 HP/HT Rheometer Software Version 3 is installed in the folder:

C:\Program Files\M5600v3

Or, if you specified a different folder during initial installation, open that folder instead.

Some versions of software may contain additional database file(s) in this folder too:

C:\Users\[YOUR_ACCOUNT]\AppData\Local\VirtualStore\Program Files (x86)\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION]

For example, an M5600 .accdb database for versions of the M5600 HP/HT Rheometer Software before Version 3.2.0.45 may be in the C:\Program Files\M5600v3 folder AND this folder:

C:\Users\[YOUR _ACCOUNT]\AppData\Local\VirtualStore\Program Files(x86)\M5600v3

Some versions of software may contain .laccdb database file(s) in this folder too:

C:\Users\[YOUR_ACCOUNT]\AppData\Local\VirtualStore\Program Files (x86)\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION]

For example, an M5600 .laccdb database for versions of the M5600 HP/HT Rheometer Software before Version 3.2.0.45 may be in this folder:

C:\Users\[YOUR _ACCOUNT]\AppData\Local\VirtualStore\Program Files(x86)\M5600v3

If you have database files in more than one location for the same machine, the database file in the C:\Program Files\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION] location is probably inert and will likely not contain any changes you make to the database, such as adding, modifying, or deleting tests or test result files. In this case, the database that does contain your saved test data is likely the .mdb or .accdb one contained in the C:\Users\[YOUR_ACCOUNT]\AppData\Local\VirtualStore\Program Files (x86)\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION] folder. This discrepancy was previously necessary to accommodate the latest updates in Windows Vista/7.

Any .laccdb file you find is inert.

The default installation folder containing your database under Windows 8 or 8.1 is:

C:\Program Files (x86)\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION]

Or, if you specified a different folder during initial installation, open that folder instead.

The default installation folder containing your database file(s) under Windows 10 is:

C:\Program Files\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION]

For example, the M5600 .accdb database for M5600 HP/HT Rheometer Software Version 3 is installed in the folder:

C:\Program Files\M5600v3

Or, if you specified a different folder during initial installation, open that folder instead.

Some versions of software may contain additional database file(s) in this folder too:

C:\Users\[YOUR_ACCOUNT]\AppData\Local\VirtualStore\Program Files (x86)\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION]

For example, an M5600 .accdb database for versions of the M5600 HP/HT Rheometer Software before Version 3.2.0.45 may be in the C:\Program Files\M5600v3 folder AND this folder:

C:\Users\[YOUR _ACCOUNT]\AppData\Local\VirtualStore\Program Files(x86)\M5600v3

Some versions of software may contain .laccdb database file(s) in this folder too:

C:\Users\[YOUR_ACCOUNT]\AppData\Local\VirtualStore\Program Files (x86)\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION]

For example, an M5600 .laccdb database for versions of the M5600 HP/HT Rheometer Software before Version 3.2.0.45 may be in this folder:

C:\Users\[YOUR _ACCOUNT]\AppData\Local\VirtualStore\Program Files(x86)\M5600v3

If you have database files in more than one location for the same machine, the database file in the C:\Program Files\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION] location is probably inert and will likely not contain any changes you make to the database, such as adding, modifying, or deleting tests or test result files. In this case, the database that does contain your saved test data is likely the .mdb or .accdb one contained in the C:\Users\[YOUR_ACCOUNT]\AppData\Local\VirtualStore\Program Files (x86)\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION] folder. This discrepancy was previously necessary to accommodate the latest updates in Windows 10.

Any .laccdb file you find is inert.

Step 6: Make sure that at least one of the database files you found is the latest database file with your testing data. To do this, check the extension, date stamp, and file size.

a. The extension MUST be .mdb or .accdb.

b. The date stamp MUST correspond to the date you last performed testing.

c. The file size should be larger than the size of the blank database that appeared in the C:\Program Files\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION] folder when the program was first installed. (If you have database files in more than one location for the same machine, the one that is the latest database will have a date stamp that corresponds with the last testing date and will be a larger file size than the other database files.)

Step 7: Make a backup of ALL the database files (.mdb, .accdb, and .laccdb) for the machine that were found after searching and were in the listed locations above specified for your operating system, even if they are inert. This is to ensure that the user has a copy of ALL database files just in case the wrong one was chosen for latest database file.

To do this, copy all database file(s) and save them in a safe place. Two backup copies of each database file required for your machine are recommended, one on your PC and one on an external USB. It is strongly recommended to place each backup database file in a separate folder, labeled with a reference to the directory it was found in for future reference.

Step 8: Make backups periodically as needed to ensure your data is safe.

To restore a backed-up database file:
Step 1: Make sure you have a backup of your database with the latest testing data before proceeding. See the steps in the To back up your database file(s), perform the following: section above for detailed instructions, especially step 6.

Step 2: Log into an administrator account that is performing testing.

Step 3: Restore the latest database file. To do this, copy your .mbd or .accdb database file backup to the C:\Program Files\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION] folder, overwriting the default database file. Or, if you specified a different folder during initial installation, overwrite to that folder instead.

Step 4: The software should now contain your saved testing data. Open the software to verify.

If not, upgrade to the latest software version, then perform step 3 above again. If no updates are available, and if you have database files in more than one location for the same machine, also copy your database backup to the C:\Users\[YOUR_ACCOUNT]\AppData\Local\VirtualStore\Program Files (x86)\[INSTRUMENT MODEL NUMBER, SOFTWARE NAME, and/or VERSION] folder, then open the software to verify your latest testing data appears.
NOTE: Carefully read the Terms of Use and End User License Agreement. By accessing or using any software download links on this page, you agree to the terms and conditions set forth in the Terms of Use and End User License Agreement and are bound by these terms.

M2200 HP/HT LUBRICITY, DYNAMIC FILTRATION, & DRILLING SIMULATION TESTER

Updating M2200 PC Software:
  1. Download the M2200 Update (Version 1.1.0.8) file. (Last uploaded 03-18-2021, 10.425 MB)
  2. After downloading this file, copy it into the folder with the existing version of the file to overwrite it.
  3. NOTE: To find the right folder, right-click on the shortcut of the application, then select "Open file location." The existing file is usually located in the C:/Lubricity/Lubricity Tester folder, but this location may differ depending on the location selected when the program was first installed.
M2200 Release Notes
V.1.1.0.8 (03-18-2021):
  1. Lubricity calibration changed to Lubricity verification. Related corresponding changes also made.
  2. Attempted resolution of intermittent temperature measurement in realtime test functionality.
V.1.1.0.7 (02-09-2021):
  1. Corrected drilling rate calculation method.
V.1.1.0.6 (09-24-2020):
  1. Added quotation mark error message. Appears when an quotation mark (invalid character) is entered for a test name.
V.1.1.0.4 (09-28-18):
  1. Added equation for the air pressure (psi) to the support force (lbs) per customer requirement.

M3500 VISCOMETER

Updating Gracedaq for M3500a™ to version 1.1.9:

Gracedaq for M3500a™ software update includes an executable (".exe") file, a report (".rpt") file, and a database (".mdb") file.

  1. Download the following three files to your desktop, or to a folder on your hard drive:
    M3500a.exe (Last updated 07-15-2008, 684 KB)
    M3500a2.rpt (Last updated 07-15-2008, 10.7 KB)
    M3500a-db.zip (Last updated 07-15-2008, 196 KB)
  2. Replace the existing version.
Updating M3500Frac.exe:
  1. Download the M3500Frac v.1.0.3 update here. (Last updated 07-15-2008, 664 KB)
  2. Run the update file to replace the existing version.
Updating M3500pH.exe:
  1. Download the M3600pH update here. (Last updated 07-16-2009, 664 KB)
  2. Run the update file to replace the existing version.
IMPORTANT NOTE: Gracedaq for M3500a™ v. 1.1.9 is incompatible with database files created by all previous versions. If you want to use an existing database file created using a version of Gracedaq for M3500a™ earlier than v. 1.1.9, do not update your Gracedaq for M3500a™ software.

M3600 AUTOMATIC RHEOMETER AND M3700 VISCOMETER

Updating M3600DAQ:
  1. Download the M3600DAQ V2.0.0.13 update here. (Last updated 02-18-2019, 1.23 MB)
  2. Run the update file to replace the existing version.
Updating M3600FRAC:
IMPORTANT: Please check the serial number on your instrument. If your unit has M3600-581 or earlier, DO NOT download the update below. Please download this M3600FRAC v1.2.0.22 update instead. Please call us if you have questions at (713) 783-1560.
IMPORTANT: Download the update below only if your unit's serial number is later than M3600-581.
  1. Download the M3600FRAC Update (Version 1.3.0.5) here. (Last updated 07-24-2019, 618 KB)
  2. Run the update file to replace the existing version.
M3600DAQ Release Notes:
V.2.0.0.13 (02-18-19):
  1. Included R7B7 functions.
V.2.0.0.12 (06-05-18):
  1. Updated version.
V.2.0.0.11 (04-20-18):
  1. Updated version to improve UI.
V.2.0.0.10 (06-20-17):
  1. Updated PV and YP data in the details Excel export function.
V.2.0.0.9 (04-06-17):
  1. Added PV and YP data in the details Excel export function.
V.2.0.0.7 (06-20-14):
  1. Modified legacy code left over from 2.0.0.05 which caused a run-time error when creating test file over a set number of data points.
V.2.0.0.5 (09-11-13):
  1. Bug fixes
V.2.0.0.2 (12-06-12):
  1. Removed Calibration Check button.
M3600FRAC Release Notes:
Version 1.3.0.5 (07-24-2020):
  1. Feature: Added functionality for M3700 viscometer.
  2. Bug Fix: Fixed bug that occurred when instrument ramped up more than 15 times.
V.1.3.0.4 (02-07-19):
  1. Updated to improve user experience.
V.1.3.0.3 (07-17-18):
  1. Minor improvement features to enhance UX.
V.1.3.0.2 (04-20-18):
  1. Minor improvement features to enhance UX.
V.1.3.0.1 (03-30-18):
  1. Major improvements to the import/export function for sequence files and drilling data.
V.1.2.0.28 (03-26-18):
  1. Created drill data; created import/export function for sequence files.
V.1.2.0.23 (08-02-17):
  1. Changed the communication protocol.
V.1.2.0.22 (06-20-17):
  1. Updated the PV and YP data in the details Excel export function.
V.1.2.0.17 (03-15-17):
  1. Added PV and YP data in the details Excel export function.
V.1.2.0.17 (08-31-15):
  1. Resolved issue occuring on home screen.
  2. Revised variable selection.
V.1.2.0.15 (07-02-15):
  1. Fixed bugs that resulted in user errors during testing.
V.1.2.0.12 (03-24-14):
  1. Introduced the ability to re-size the Real Time Test screen using a numerical control on the Hardware & Misc. Setup tab. To reset the display to the default screen size, a menu item called ReSet has been added to the main menu.
V.1.2.0.11 (09-06-13):
  1. Bug fixed

M4600 LSM

Updating M4600daq.exe
  1. Download the M4600DAQ_v2008 update here. (Last updated 02-06-17, 2.09 MB)
  2. Run the update file to replace the existing version.
M4600DAQ Change Log
V.2.0.0.8 (02-06-17):
  1. Updated temperature settings.
V.2.0.0.7 (08-19-15):
  1. Corrected errors in the program.
V.2.0.0.6 (05-13-15):
  1. Created a patch to update and fix some areas of the program.

V.2.0.0.4 (08-25-14):
  1. Fixed a glitch giving some customers errors within the program
V.2.0.0.3 (05-01-12):
  1. Fixed bug preventing proper temperature setting during preheat.

M5052FRAC

Updating M5052Frac
  1. Download the M5052 file here. (Last uploaded 8-31-2015, 888 KB).
  2. Run the update file to replace the existing version.

M5500 RHEOMETER

Updating M5500Frac
  1. Download the M5500Frac.exe update file here. (Last updated 12-27-2011, 956 KB).
  2. Run the update file to replace the existing version.
M5500 PC Change Log:
V.1.2.0.2 (12-27-11):
  1. Modified call to Microsoft Excel to allow the use of Microsoft Excel 2010 or later.

M5600 HPHT RHEOMETER

M5600 PC Version 3 - Updating M5600 PC v3
IMPORTANT: If you are not running M5600 PC v3, do not download and install this update, as it is incompatible with databases created with M5600 PC v2.
  1. Download the M5600 Version 3.2.0.45 update here. (Last updated 12-31-2020, 2.204 MB) Only install this update if you have version 3 or later. This update is incompatible with version 2 of the software or earlier.
  2. To install this item, do not double-click on the file. Instead, right-click on the M5600 icon installed on the desktop and select open file location. Copy the M5600_v3.exe file into the folder that pops up. Windows will display a message to confirm if it is okay to overwrite the file. Select the Replace the file in the destination option to continue.
  3. Be sure that you are installing the latest version of M5600_v3.exe in the proper directory (i.e., your original installation directory).

If you have already downloaded M5600 v3.2.0.41 and are experiencing issues regarding a Pesgo32c.ocx file, please use the hyperlink below to download the file.

  1. Download the M5600 Pesgo32c.ocx here. (Last updated 12-15-16, 1.12 MB)
  2. Place the file in the proper M5600 folder.
  3. Restart the M5600 Software before beginning a new testing.
M5600 PC Version 2 - Updating M5600 PC v2
IMPORTANT: If you are upgrading a version of M5600.exe v.2.1.0.7 or later, you do not need to download a new version of M5600.mdb.
  1. Download the M5600 v.2.2.0.3 update here. (Last updated 12-22-11, 1.40 MB).
  2. Run the update file to replace the existing version.
M5600 Database File - Updating M5600.mdb
IMPORTANT: This download is only for updating M5600.mdb (to replace database files created with M5600 PC™ versions earlier than M5600 PC v.2.1.0.7)
  1. Download the M5600.mdb file here. (Last updated 04-27-2009, 2.10 MB).
  2. Please note that the M5600.mdb file is in .zip format. You must first unzip the file before it can be used by M5600 PC. Then, replace the existing version with the current version.
M5600 Software Version 3 Release Notes
V.3.2.0.45 (12-31-2020):
  1. Fixed database bug.
V.3.2.0.43 (08-15-2018):
  1. Updated display.
V.3.2.0.41 (03-15-17):
  1. Resolved an issue with Fann 35 degree.
  2. Fixed issue with missing Pesgo32c.ocx file.
V.3.2.0.41 (12-14-16):
  1. Resolved an issue with Fann 35 degree.
  2. Fixed issue with missing Pesgo32c.ocx file.
V.3.2.0.39 (11-06-15):
  1. Repaired software glitch.
V.3.2.0.38 (05-01-15):
  1. Revised minor technical issue with charting capabilities.
V.3.2.0.36 (05-01-15):
  1. Updated the oscillatory function to operate more quietly and seamlessly.
V.3.2.0.35 (01-23-15):
  1. Fixed a bug on the main menu home screen. Repaired the 'Edit Test Info' button so the user can input additional testing information without error pop-up message.
V.3.2.0.30 (09-29-14):
  1. Repaired the 'self-zero peak' and 'before run ramp' features, updated chart with detail result option. Inserted a 'press calibrate done' display button and fixed the setup/export & setup/import columns.
V.3.2.0.29 (04-18-14):
  1. Fixed a bug preventing exporting images from the chart. (Right-click on the chart to see the export option.
V.3.2.0.28 (03-24-14):
  1. Fixed a bug in which too much text entered into the test information windows would cause a crash instead of generating an error.
V.3.2.0.27 (01-07-14):
  1. Fixed a bug - the Setup screen will now resize if the screen size value is changed in the Hardware & Misc Setup tab.
M5600 PC V2 Change Log
V.2.2.0.3 (12-22-11):
  1. Modified call to Microsoft Excel to allow the use of Microsoft Excel 2010
V.2.2.0.2 (10-11-10):
  1. Fixed database-connectivity issues; improved test search function; improved chart display for real time tests.
V.2.2.0.1 (08-31-10):
  1. Added Search Test function to Open Saved Test window.

M7270 DUAL CELL CONSISTOMETER / M7280 HPHT DUAL CELL CONSISTOMETER

Updating to version 1.0.0.10:
  1. Download the M7270.exe file. (Last updated 12-05-17, 9.94 MB)
  2. Then, copy and paste the file to the correct folder on your PC to replace the existing version.
  3. Open and run the software to begin testing.
M7270 / M7280 PC Change Log:
V.1.0.0.09 (12-05-17):
  1. Update software and enhanced UX.
V.1.0.0.08 (02-24-17):
  1. Changed max consistency to 150 and fixed minor bugs.
V.1.0.0.07 (01-20-17):
  1. Fixed minor issue affecting software performance.
V.1.0.0.06 (01-13-17):
  1. Updated Sequence File Name options to allow double or single quotes.
  2. You can only use double quotes OR single quotes, not both when naming a sequence and test.
V.1.0.0.05 (01-12-17):
  1. Updated the software to fix minor issue.

NOTE : This update file is used for both the M7270 Dual Cell Consistometer and the M7280 HPHT Dual Cell Consistometer.

M7350 UCA

Updating to version 1.0.0.11:
  1. Download the M7350 Update (Version 1.0.0.11) file. (Last updated 06-07-2021, 9.703 MB)
  2. Do not double-click on the file to update. Instead, right-click on the M7350 icon (usually installed on the desktop) and select Open file location. Copy the M7350_UCA.exe file into the folder that pops up. Windows will display a message to confirm if it is okay to overwrite the file. Select the Replace the file in the destination option to continue.
  3. Be sure that you are installing the latest version of M7350_UCA.exe in the proper directory (i.e., your original installation directory).
  4. After updating, run the software to begin testing.
M7350 PC Change Log:
V.1.0.0.11 (06-07-2021):
  1. Add input cement density feature in realtime test and after test.
  2. Add calculate and export feature for the cement ZCMT value (unit MRayl).
V.1.0.0.10 (01-27-2020):
  1. Fixed program crashes caused by running unit for some time.
  2. Fixed temperature bug. Temperature now sets correctly.
V.1.0.0.9 (11-21-17):
  1. Improved software performance
V.1.0.0.8 (08-15-17):
  1. Updated Software and improve performance
V.1.0.0.7 (06-22-17):
  1. Updated Software
V.1.0.0.6 (05-31-17):
  1. Updated graphics palette
V.1.0.0.5 (05-17-17):
  1. Corrected the Overlap units for psi and C°
V.1.0.0.4 (04-24-17):
  1. Fixed a bug.
V.1.0.0.3 (04-12-17):
  1. Added PV and YP data in the details Excel export function.

M7360 Ultrasonic Cement Analyzer

Updating to Version 1.0.0.13:
  1. Download M7360 Update (Version 1.0.0.13) file. (Last updated 01-19-2022, 9.94 MB)
  2. Do not double-click on file to update. Instead, right-click on M7360 program's shortcut icon (desktop shortcut may be available, if option was selected during installation) and select Open file location.
  3. Copy M7360_UCA.exe file into folder that pops up. Windows will display a message to confirm overwrite of file. Select Replace the file in the destination option to continue.
  4. Ensure M7360_UCA.exe is in proper directory (original installation directory).
  5. After updating, run software to begin testing.
M7360 Software Release Notes
Version 1.0.0.13 (01-19-2022):

  1. Added Cement Density field to Edit File Info and Input Test Information windows. Populates ZCMT (MRayl) in Test Progress Information table after testing.
Version 1.0.0.12 (11-19-2018):

  1. Improved connectivity and operation. Software can now simultaneously connect to up to 4 units and run continuously for up to 7 days.

M7370 Automatic Pressure Control Twin Cell UCA

Updating to Version 2.0.0.7:
  1. Download the M7370 Update (Version 2.0.0.7) file. (Last updated 12-08-2021, 10.79 MB)
  2. Do not double-click on the file to update. Instead, right-click on the M7370 program's shortcut icon (desktop shortcut may be available, if checkbox was selected during installation) and select Open file location. Copy the M7370.exe file into the folder that pops up. Windows will display a message to confirm if it is okay to overwrite the file. Select the Replace the file in the destination option to continue.
  3. Be sure that you are installing the latest version of M7370.exe in the proper directory (i.e., your original installation directory).
  4. After updating, run the software to begin testing.
M7370 Software Release Notes
Version 2.0.0.7 (12-08-2021):
  1. Added new safety feature that automatically sets temperature to 0 after test sequences complete (if not manually performed by the user). Ensures cell does not unintentionally heat up next time machine is turned on.
Version 2.0.0.6 (11-29-2021):
  1. Improved program performance.
  2. Fixed communication loss for lengthy (+9 hrs.) dual cell testing.
Version 2.0.0.5 (01-18-2021):
  1. Improved program performance.
  2. Fixed freezing/crashing problem that occured when program ran for extended periods.
Version 2.0.0.4 (01-12-2021):
  1. Fixed problem that caused program slowdown.

M7500 ULTRA HPHT RHEOMETER / M8500 SAGGING TESTER

M7500 Version 2 - Updating M7500 v2
  1. Download the M7500 v.2.0.0.29 update file here. (Last updated 02-02-18, 2.26 MB).
  2. Run the update file to replace the existing version.
IMPORTANT : Do not apply this update if you have M7500daq version 1.2.0.23 or earlier. This update is intended for users of M7500daq_v2. The version 2 software is not compatible with the database files created by version 1.2.0.23 or earlier.
M7500daq Version 1 - Updating M7500daq v1
  1. Download the M7500daq v.1.2.0.23 update file here. (Last updated 06-20-12, 1.30 MB).
  2. Run the update file to replace the existing version.
IMPORTANT : M7500daq™ is used for both the M7500 Ultra HPHT Rheometer and the M8500 HPHT Dynamic Sagging Tester. This version of M7500daq.exe is compatible with both the M7500-2 (hardware capable of pressure up to 20,000 psi) and the M7500-3 (hardware capable of pressure up to 30,000 psi.) It will not enable M7500-2 hardware to pressurize higher than 20,000 psi.
M7500 V2 Change Log
V.2.0.0.29 (02-02-18):
  1. Updated features in M7500 to enhance user experience.

V.2.0.0.28 (11-03-17):
  1. Added integers to the plot graph.

V.2.0.0.24 (10-21-16):
  1. Updated the pressure control.

V.2.0.0.23 (05-08-15):
  1. Fixed minor bug affecting heat conditions during testing.

V.2.0.0.22 (04-22-15):
  1. Improved temperature settings to eliminate fluctuation errors.

V.2.0.0.14 (07-22-14):
  1. Corrected issue with .CSV file generation.

V.2.0.0.13 (06-20-14):
  1. Added new plottable data point: Fann35 to Real Time Test mode.

V.2.0.0.12 (04-21-14):
  1. Improved performance & bug fixes.
  2. Added temperature ramp and pressure ramp
M7500daq V1 Change Log
V.1.2.0.23 (06-20-12):
  1. Removed bug which interfered with N" and K" display

V.1.2.0.22 (02-21-12):
  1. General UI and performance improvements.

V.1.2.0.21 (01-26-12):
  1. Corrected error causing automatic shutdown.

M7540 CONSISTOMETER/SGS TESTER

IMPORTANT: Please check the version number within your software program under the HELP/ABOUT menu. If your software is v1.0.XX, only download version 1.0.XX updates. If your version is v2.0.XX, only download version 2 updates. Please call us if you have questions.
Updating to Version 2.0.0.f (NEW MOTOR):
  1. Download the M7540 Update Version 2.0.0.f.exe file. (Last updated 02-24-2021, 12.26 MB)
  2. Then, copy and paste the file to the M7540 folder on your PC to replace the existing version.
  3. Open and run the software to begin testing.
Updating to Version 1.0.0.5 (OLD MOTOR):
  1. Download the M7540_Main.exe file. (Last updated 05-04-17, 11.9 MB)
  2. Then, copy and paste the file to the M7540 folder on your PC to replace the existing version.
  3. Open and run the software to begin testing.
M7540 Software Release Notes (New Motor):
V.2.0.0.f (02-24-2021):
  1. Fixed display bug that occured during shutdown.
V.2.0.0.e (11-14-2019):
  1. Fixed unit display bug.
V.2.0.0.c (08-13-18):
  1. Updated an issue with the unit display.
V.2.0.0.b (08-08-18):
  1. Fixed unit display problem.
V.2.0.0.a (12-13-17):
  1. Added unit feature.
M7540 Software Release Notes (Old Motor):
V.1.0.0.5 (05-04-17):
  1. Fix temperature/pressure control problem for low rate.
  2. Improve both temp and pressure control.
V.1.0.0.4 (05-02-17):
  1. Updated the software for better temperature control.
V.1.0.0.3 (01-12-17):
  1. Updated Sequence File Name options to allow double or single quotes.
  2. You can only use double quotes OR single quotes, not both when naming a sequence and test.
V.1.0.0.2 (01-11-17):
  1. Updated the software and fixed a minor bug.

M9145 Porosimeter

Updating to latest version:
  1. Download the M9145_Setup.exe file. (Last updated 06-07-17, 1.98 MB)
  2. Then, copy and paste the file to the M9145 folder on your PC to replace your existing version.
  3. Open and run the software to begin testing.
M9145 PC Change Log:
(06-07-17):
  1. Fixed a minor bug in the software.

M9250 Friction Flow Loop

Follow the instructions below to replace the existing M9250 software version:
  1. First, download the SSI M1-Class pump USB driver by visiting the Teledyne website here.
  2. Scroll to the bottom of the page. Under Drivers Downloads, click NXP Virtual COM Port USB Drivers (Micro USB) (1.7 KB) to download the file to your PC.
  3. Extract the file and install to your PC.
  4. Next, download this M9250 Setup file. (Last updated 09-14-2018, 4.34 MB)
  5. Then, copy and paste the M9250 Setup File into your C:\Apps\M9250-BJ folder directory.
  6. Open and run the software to begin testing.
M9250 PC Change Log:
(09-14-18):
  1. Updated software with additional SSI pump USB driver.
(06-07-17):
  1. Fixed a minor issue in the software.

M9500

Updating to latest version:
  1. Download the M9500 Update_V1002.exe file. (Last updated 07-17-17, 4.9 MB)
  2. Then, double click M9500 Update_V1002.exe file and follow the promps to complete the installation.".
  3. Open and run the software to begin testing.
M9500 PC Change Log:
(07-17-17):
  1. Fixed a minor bug in the software.

M9710 FLOW ASSURANCE SYSTEM

Updating to version 1.0.0.6:
  1. Download the M9710.exe file. (Last uploaded 01-22-2018, 3.33 MB)
  2. Follow the instructions within the software installer.
  3. Once installation completes, open and run the software to begin testing.
M9710 PC Change Log:
V.1.0.0.6 (01-22-18):
  1. Updated the temperature display from scientific to regular.
V.1.0.0.4 (07-31-17):
  1. Changing the hardware settings.
V.1.0.0.3 (07-26-17):
  1. Fixed irregularities in the software causing errors.
V.1.0.0.2T (07-25-17):
  1. Fixed some bugs presenting issues.
V.1.0.0.1 (05-02-17):
  1. Updated the software to enhance user experience.

M9720 MICROMODEL PHASE BEHAVIOR SYSTEM

Updating to version 1.0.0.3:
  1. Download the M9720_Main.exe file. (Last uploaded 10-18-17, 4.50 MB)
  2. Open and run the program. Follow the instructions from the software installer.
  3. Open the software to begin testing.
M9720 PC Change Log:
V.1.0.0.3 (10-18-17):
  1. Updated a minor technical issue in the software.